The MindMaster Bio 8 is the most comprehensive biofeedback system in the MindMaster Bio series. With eight biofeedback parameters — including 3-channel EMG, skin conductance (EDA), temperature, pulse and respiration — and all four software modules included, the Bio 8 provides maximum flexibility for professional biofeedback practice. If you are looking to buy a complete biofeedback system that makes no compromises, the Bio 8 is the right choice.
This complete system is designed for experienced practitioners, clinics and institutions that require the full spectrum of peripheral biofeedback. All four included software modules — HRV Training, Stress Test, EMG Training and EMG Assessment — are ready to use immediately after installation. Compared to the Bio 7, the Bio 8 adds a third EMG channel and includes all modules at no additional cost. All required sensors, cables and electrodes are delivered in the robust transport case.
Contents:
- MindMaster Bio 8 device in case
- USB cable
- 6 EXG cables for EMG incl. snap adapter, 1.8m
- 2 DRL cables for EMG incl. snap adapter, 1.8m
- EMG single-use adhesive electrodes, 50 pieces
- Isopropyl alcohol 70%, 100ml
- 1 EDA cable with two snap ends, 1.8m
- EDA gel electrodes, 3 pieces, incl. 99 adhesive rings
- EDA electrode gel, 113g
- EDA velcro electrodes, 10 pieces
- Temperature sensor, 1.8m, incl. Leukosilk
- Temperature sensor fingerclip (3D printed)
- Pulse sensor, Hard-Tip, for adults, 90cm
- Pulse sensor for temporal artery application
- 2 Respiration belts for thorax and abdomen
- Respiration belt adapter
- Biofeedback software
- ALL Biofeedback Software Modules included:
- HRV Training (Heart Rate Variability)
- Stress Test (Stress Profile Assessment)
- EMG Training (Muscle Training)
- EMG Assessment (Muscle Diagnostics)
- 4 Biofeedback templates
- Printed instruction manuals
- Software on USB stick
MindMaster devices are currently offered with USB connection to PC only. Bluetooth® connectivity is no longer available.
Please allow approximately 14 days for delivery due to individual configuration.
From the date of purchase, all MindMaster customers receive 8 weeks of complimentary support via phone and email, including remote assistance. After the initial period, continued support is available through a Support and Software Contract which also includes free software updates.
Integrated Biofeedback Parameters
The MindMaster Bio 8 offers eight biofeedback parameters — the most comprehensive peripheral biofeedback coverage in the Bio series:
- EMG (Electromyography) — 3 Channels: The Bio 8 is the only Bio model offering three EMG channels. This enables complex muscle analysis — for example, simultaneous measurement of left and right sides plus a reference muscle group, or mapping entire muscle chains.
- EDA (Electrodermal Activity / Skin Conductance): Sensitive indicator of sympathetic arousal for stress management and relaxation training.
- Temperature: Peripheral skin temperature measurement reflecting autonomic regulation and blood flow.
- Pulse / Heart Rate: Two measurement methods — finger pulse sensor and temporal artery sensor. Foundation for HRV training and cardiovascular biofeedback.
- Respiration: Two respiration belts for thorax and abdomen enable simultaneous chest and abdominal breathing measurement — ideal for differentiated breathing training.
Biofeedback Performance Software
The included Biofeedback Performance Software provides 7 ready-to-use training screens — each with a trainer screen and a feedback screen for professional dual-monitor operation:
- Skin Temperature: Hand warming training with threshold or direction-based training. Feedback via bar graphs, video or images.
- Respiration: 1- or 2-channel breathing training (chest and abdomen) with adjustable breathing pacer and balloon animation.
- EDA / Skin Conductance: Training to reduce sympathetic arousal with spontaneous fluctuation detection and various feedback options.
- Pulse / Heart Rate: BVP measurement at finger or temple with heart rate and amplitude display.
- 1-Channel EMG: Muscle activity training with impedance measurement, configurable filters and animations (balloon, human figure).
- 2-Channel EMG: Side comparison of both channels with animations (seesaw, bowling, underwater, space) and permanent impedance measurement.
- Individual Screen: 3 parameters freely selectable — for completely flexible training design.








General Software Features: Client management with archive function, VLC Media Player integration (videos as feedback), audio/music feedback with custom files, events and markers during recording (Ctrl+1-9), vibration feedback (MindPet / vibration cushion), permanent real-time impedance measurement, and data export in XDF and Excel format.
Biofeedback Software Modules
The MindMaster Bio 8 includes all four software modules — at no additional cost. Each module extends the base software with specialized training and diagnostic capabilities:
HRV Training (Heart Rate Variability)
Heart rate variability training using pulse and respiration sensors. The module provides real-time HRV visualization, multiple feedback modes (visual and auditory) and integrated breathing guidance. HRV is a recognized marker of autonomic nervous system adaptability and is used in stress management, resilience training and cardiovascular training.
Stress Test (Stress Profile Assessment)
Standardized stress profile assessment using up to five parameters simultaneously. The automated protocol includes stressor and relaxation phases over approximately 21 minutes, featuring an integrated Stroop test as a cognitive stressor. The result is an objective profile of individual stress response and recovery capacity — ideal for baseline and progress assessments.
EMG Training (Muscle Training)
2-channel EMG muscle training with various feedback modes, impedance measurement and flexible visualizations. The module supports systematic muscle training and relaxation with real-time feedback. Multiple training modes allow adaptation to different therapeutic objectives.
EMG Assessment (Muscle Diagnostics)
EMG-based muscle diagnostics and systematic assessment. This module enables standardized baseline and progress evaluations of muscle activity. Structured test protocols deliver reproducible results for documentation and outcome tracking.
Advantages of the MindMaster Bio 8
The MindMaster Bio 8 delivers the maximum feature set for professional biofeedback:
- Complete system at no extra cost: All four software modules are included — HRV Training, Stress Test, EMG Training and EMG Assessment are ready to use immediately
- 3-Channel EMG: The only Bio model offering three EMG channels for complex muscle analysis and differentiated diagnostics
- Maximum flexibility: 8 parameters and all modules enable immediate deployment across every biofeedback application area
- Two respiration belts: Simultaneous thoracic and abdominal breathing measurement for differentiated respiration training
- Professional transport case: All sensors, cables and electrodes organized in the robust case
- 8 weeks complimentary support: Phone and email support including remote assistance from date of purchase
Modular Concept & Upgradeability
All MindMaster devices (except Neuro 4) are built on the same modular platform. The Bio 8 can be upgraded at any time to the BioNeuro 9 or BioNeuro 11 — adding neurofeedback with up to 6-channel EEG and SCP training. The cost is the price difference plus 199 EUR assembly and shipping fee.
Frequently Asked Questions
Are all software modules really included with the MindMaster Bio 8?
Yes, all four software modules — HRV Training, Stress Test, EMG Training and EMG Assessment — are included with the Bio 8. No modules need to be ordered or purchased separately.
What can the Bio 8 do that the Bio 7 cannot?
The Bio 8 offers two key enhancements over the Bio 7: first, 3-channel EMG instead of 2-channel EMG for more complex muscle analysis; and second, all four software modules included rather than just one module of choice. Additionally, the Bio 8 includes two respiration belts (thorax and abdomen) for differentiated breathing training.
Who is the MindMaster Bio 8 suitable for?
The Bio 8 is designed for experienced practitioners, clinics and institutions that require the full spectrum of peripheral biofeedback without ordering modules individually. With all modules included, the Bio 8 is immediately ready for HRV training, stress diagnostics and differentiated EMG training.
Can I upgrade from the Bio 8 to a BioNeuro system?
Yes, the Bio 8 can be upgraded at any time to the BioNeuro 9 or BioNeuro 11. All MindMaster devices (except Neuro 4) are built on the same modular platform. The cost is the price difference plus 199 EUR assembly and shipping fee. Send in your device and receive it back with expanded neurofeedback functionality (up to 6-channel EEG incl. SCP training with the BioNeuro 11).




Reviews